Speed control of slipring Induction Motor.

STEP 1: Make connections as per the instructions given below. If the wire is wrongly connected, Click on node number to detach the wire.

From 1 2 3 4 5 6 7 9 10 11 16 17 18 19 20
To 21 22 23 12 13 12 8 15 12 17 13 14 24 25 26

STEP 2: Click on "Check" button for checking the connections.

  • If connection is correct, an alert appears. Click ok. Now, go to step 4.
  • If connection is wrong, an alert appears. Click ok. Now, go to step 3.

  • STEP 3: Check the connection and either detach the incorrect wire connection or Click on Reset button and start from step 1.

    STEP 4: Switch on the MCB.

    STEP 5: Click on the autotransformer knob.

    STEP 6: Slide the knob of the Rheostat to change the resistance.

    STEP 7: Click on "Add to table" button to insert the readings in the table.

    STEP 8: Follow the procedure from step 6 to step 7, till you have the 6 readings in the table.

    STEP 9: After taking minimum 6 readings, Click on the "Graph" button.

    STEP 10: Click on "Print" button to print the full connections with graph and table.